Cookies

We use cookies to give you the best possible experience on our website. For more information about the cookies we use, see our cookies page here.

LV / EN / RU

Cart

Subtotal:

0.00 €

ATW heat pump Mitsubishi Power Inverter, 4 - 6 kW

Categories: MITSUBISHI

The Mitsubishi Power inverter (7.3; 9.0; or 10.4 kW models) air-to-water heat pump is the ideal solution for any new-build or renovated home. It is flexible and easy to combine (e.g. with a central heating fireplace for a hybrid heating system). Switching to a heat pump heating system can save up to 75% on heating costs thanks to its high efficiency.

This version of the unit combines a Mitsubishi Power Inverter outdoor unit with a dedicated heat exchanger, the pressure and flow sensors necessary for its efficient operation, and a Mitsubishi control unit.

  • Manufacturer: MITSUBISHI ELECTRIC (Japan)
  • Warranty: 5 years
ACCESSORIES AND INSTALLATION MATERIALS

Mitsubishi PUD SWM/SHWM technical data (ENG, PDF)

Mitsubishi PUD SWM/SHWM installation manual (MULTI, PDF)

For your information:

  • Copper pipes and ground or wall brackets are required when planning the installation, depending on the installation location.

OPTIONAL EXTRAS:

  • Pressure sensor for Mitsubishi external unit (mandatory) - 52€
  • Flow sensor for Mitsubishi external unit (mandatory) - 155€
  • TH1 room temperature sensor - 63€
  • THW5 hot water temperature sensor - 37€
  • THW6/THW7 heating return/return temperature sensors - 52€
  • THW8/THW9 heating return temperature sensors - 52€
  • THWB1/THWB2 boiler return and return temperature sensors - 73€
  • WiFi adapter - 141€
  • Mitsubishi double pump group for control of two heating circuits TWO ZONE KIT - 1190€
  • Mounting bracket for Mitsubishi outdoor unit - 208€
  • Bath heating cable for external unit - 42€
  • Mounting bracket with condensate collection bath and heating cable for outdoor unit - 260€

Available in stock
5,310.00 - 6,890.00 €
Price with VAT

 

External unit parametres POWER INVERTER
PUD-SWM80YAA PUD-SWM100YAA PUD-SWM120YAA
HEATING (C) Power / Energy class / SCOP at 35°C / ɳs % kW / reit. / SCOP / % 8/A++/3,45/138 10/A++/3,63/145 12/A++/3,48/139
(C) Power / Energy class / SCOP at 55°C / ɳs % kW / reit. / SCOP / % 8/A+/2,73/109 10/A+/2,73/109 12/A+/2,7/108
A7/W35 / Capacity / el. consumption / COP kW / kW / COP 6,0/1,26/4,76 8,0/1,6/5,0 10,0/2,13/4,70
Capacity at -15°C/+35°C kW 7.3 9 10.4
Capacity at -15°C/+50°C kW 6.6 8.5 9.5
Capacity at -25°C/+45°C kW 4.7 6.9 8
Capacity at -28°C/+45°C kW - - -
Min-Nom-Max capacity at A2/W35 kW 3,1 - 8,0 - 9,3 3,2 - 10,0 - 12,1 3,2 - 12,0 - 12,7
Min-Nom-Max capacity at A7/W45 kW 2,2 - 6,0 - 8,2 2,3 - 8,0 - 10,0 2,3 - 10,0 - 12,1
Dimensions (W x H x D)   mm 1050 x 1020 x 480 1050 x 1020 x 480 1050 x 1020 x 480
Weight   kg 114 120 120
Work temperature (heat / cool)   °C -25°C -25°C -25°C
Sound level (nominal heating)   A 42 44 46
Sound level (max heating)   A 56 59 60
Piping Ø (liquid/gas)   inches 1/4'' / 1/2'' 1/4'' / 1/2'' 1/4'' / 1/2''
Min/Max pipe length   m 2-30 2-30 2-30
Max. Height   m 30 30 30
Fuse   A 3x16 3x16 3x16
Work current   A 8 10 12
Electrical data   F / V / Hz 400/3/50 400/3/50 400/3/50
Flow (min-max)   l/min 9 - 22,9 14,3 - 34,4 14,3 - 34,4
Delivered piping length   m 15 15 15
Reagent     R32 R32 R32
GWP     675 675 675
Nom. Reagent amount Weight kg 1.3 1.6 1.6
CO2 ekv. ton. 0.88 1.08 1.08
Max. Reagent amount Weight kg 1.6 1.8 1.8
CO2 ekv. ton. 1.08 1.24 1.24

Become a TavaSistēma member!

Subscribe and be the first to hear about incredible discounts, new products and the latest news in the world of heating, ventilation and air conditioning!