Hygienic multifunctional tank with flow-through hot water heat exchanger and 2 heating heat exchangers HYG BR 2, 500L - 1000L

Categories: SUNSYSTEM

Multifunctional tank HYG BR 2, with a flow-through hot water heat exchanger for hygienic hot water production and two heating heat exchangers. Designed for connection to one or more heating sources, additional heating heat exchangers allow the connection of additional equipment that uses a different heat carrier (e.g. solar collector or heat pump).

Main product features:

  • Additional removable insulation with a thickness of 100 mm and a durable PVC outer shell in RAL 9006 color.
  • Insulation material used in all models: soft PU, fleece.
  • Instantaneous hot water heat exchanger made of sanitary stainless steel.
  • All threads are internal. Inlet/outlet location – 90-degree angle for easy and convenient installation. Can be installed in the corner of the boiler room.
  • Easy installation.
  • Convenient inspection opening.

Energy efficiency:

  • Directive 2010/30/EU, Regulation 812/2013.
  • Class C.

The technical data for the product can be viewed below; see the gallery for explanations of the dimensions.

Available for order

Can be combined with:

1,580.00 €
Price with VAT
Apply for loan
    HYG  BR2 500 HYG  BR2 800 HYG  BR2 1000
Capacity L 500 800 1000
Capacity of water tank DHW / Buffer tank L1/L2 22/478 25/775 25/975
Height without insulation / with insulation H, Hi, mm 1710/1750 1850/1890 2040/2090
Mounting height mm 1720 1865 2074
Diameter without insulation / with insulation D, mm Ø 650/850 Ø 790/990 Ø 790/990
Heat exchange surface E, m2 5,5 6,11 6,11
Heat exchange surface – Lower/Upper coil S1/S2 S1, S2m2 1.7/1.0 2.9/1.8 3.0/2.0
Capacity Lower/Upper coil S1/S2 L 10.5/6.2 17.9/11.1 18.5/12.3
Heating power of the lower / upper coil (from an additional heat source) kW 37/19 72/39 75/42
Lower / Upper Productivity 80оС/60оС (from an additional heat source) L/h 1590/816 3095/1677 3224/1806
Recommended Absorber Heat exchange surface of Solar Collectors m2 8,00 12,00 14,00
Operating pressure/Max. coil temperature bar/0C 16/110 16/110 16/110
Operating pressure / Max. buffer temperature bar/0C 3/95 3/95 3/95
Operating pressure / Max. DHW tube temperature. bar/0C 6/95 6/95 6/95
Weight without insulation / with insulation kg, kg i 164/176 213/229 230/248
Recommended boiler size, connected to buffer tank kW 44 75 75
Continuous outflow 10/45°C, buffer tank is charged to 65°C Е,10/45°C,L/h 1080 1840 1840
Continuous outflow 10/38°C, buffer tank is charged to 65°C. Е, 10/38°C, L/h 1350 2300 2300
Single discharge capacity up to 38°C (when the buffer is charged to 65°C) Е, 10/38°C, L 375 580 790
ΔT -temperature difference between buffer tank and DHW at flow rate  30/40/50 liters/minute Е, ΔT 6/8/12 3.5/5/8 3.5/5/8
Water stratification unit Ø, mm Ø140 Ø140 Ø140
Boiler heat carrier outlet С1, mm Rp11/2”/150 Rp11/2”/170 Rp11/2”/170
Boiler heat carrier outlet С2, mm Rp11/2”/150 Rp11/2”/170 Rp11/2”/170
Boiler heat carrier outlet C3, mm Rp11/2”/150 Rp11/2”/170 Rp11/2”/170
Outlet heat carrier/lower coil S1 S1o, mm Rp1”/325 Rp1”/350 Rp1”/390
Boiler heat carrier С4, mm Rp11/2”/430 Rp11/2”/470 Rp11/2”/500
Boiler heat carrier С5,C6 mm Rp11/2”/1030 Rp11/2”/1050 Rp11/2”/1210
Outlet heat carrier/upper coil S2 S2o, mm Rp1”/1030 Rp1”/1050 Rp1”/1210
Heat carrier inlet С7, mm Rp11/2”/1450 Rp11/2”/1550 Rp11/2”/1740
Heat carrier inlet C8, mm Rp11/2”/1450 Rp11/2”/1550 Rp11/2”/1740
Inlet heat carrier/lower coil S1 S1i, mm Rp1”/775 Rp1”/845 Rp1”/930
Inlet heat carrier/lower coil S2 S2i, mm Rp1”/1360 Rp1”/1410 Rp1”/1570
Sensor sleeve А1, mm Rp1/2”/540 Rp1/2”/590 Rp1/2”/620
Sensor sleeve А2, mm Rp1/2”/650 Rp1/2”/710 Rp1/2”/770
Sensor sleeve А3, mm Rp1/2”/1140 Rp1/2”/1160 Rp1/2”/1320
Sensor sleeve А4, mm Rp1/2”/1420 Rp1/2”/1520 Rp1/2”/1700
Boiler heat carrier / Electric heating element В, mm Rp11/2”/900 Rp11/2”/930 Rp11/2”/1050
Air Vent F, mm Rp11/2”/1710 Rp11/2”/1850 Rp11/2”/2040
Inlet/outlet DHW coil (tube) Еi/Eo, mm 250/1480 270/1580 310/1760
Rp1”