ATW heat pump Mitsubishi POWER INVERTER HYDROBOX, 8-10 kW

Categories: MITSUBISHI

The Mitsubishi Power inverter (7.3; 9.0; or 10.4 kW) air-to-water heat pump is the ideal solution for any new-build or renovated home. It is flexible and easy to combine (e.g. with a central heating fireplace for a hybrid heating system). Switching to a heat pump heating system can save up to 75% on heating costs thanks to its high efficiency.

This version of the unit consists of a Mitsubishi Power Inverter outdoor unit, combined with a Mitsubishi Ecodan indoor unit, which contains everything needed to provide heating. The integrated 200L water heating tank will give constant access to hot water.

  • Manufacturer: MITSUBISHI ELECTRIC (Japan)
  • Warranty: 5 years
ACCESSORIES AND INSTALLATION MATERIALS

Mitsubishi Hydrobox (EHSD) technical datasheet (ENG, PDF)

Mitsubishi Hydrobox (ERSE) technical datasheet (ENG, PDF)

Mitsubishi PUD SWM/SHWM technical datasheet (ENG, PDF)

Mitsubishi PUD SWM/SHWM installation manual (MULTI, PDF)

For your information:

  • Copper pipes and ground or wall brackets are required when planning the installation, depending on the installation location.

OPTIONAL EXTRAS:

  • Pressure sensor for Mitsubishi external unit - 52€
  • Flow sensor for Mitsubishi external unit - 155€
  • TH1 room temperature sensor - 63€
  • THW5 hot water temperature sensor - 37€
  • THW6/THW7 heating return/return temperature sensors - 52€
  • THW8/THW9 heating return temperature sensors - 52€
  • THWB1/THWB2 boiler return and return temperature sensors - 73€
  • WiFi adapter - 141€
  • Mitsubishi double pump group for control of two heating circuits TWO ZONE KIT - 1190€
  • Mounting bracket for Mitsubishi outdoor unit - 208€
  • Bath heating cable for external unit - 42€
  • Mounting bracket with condensate collection bath and heating cable for outdoor unit - 335€

Energy efficiency class: A++

Available in stock
6,990.00 €
6,985.00 €
Price with VAT
Apply for loan
Model   Ecodan hot water tank Hydrobox
  EHST17D-YM9D EHST20D-YM9D EHST30D-YM9ED EHSD-YM9D
Energy efficiency at +35°C Class A+++ A+++ A+++ A+++
Hot water tank Litres 170 200 300 -
Electric heater kW 3+6 3+6 3+6 3+6
Dimensions (W x H x D, (height counter with packaging) mm 595 x 1400 x 680 (1630) 595 x 1600 x 680 (1820) 595 x 2050 x 680 (2250) 530 x 800 x 360
Weight (full / empty) kg 269 / 93 314 / 106 425 / 116 49 / 44
Flow temperature, min. / max. °C 20/60 20/60 20/60 20/60
Fuse A 3 x 16 3 x 16 3 x 16 3 x 16
Electrical connection F 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50
Max. Current A 13 13 13 13
Min. / Max. Room temperature °C 0 - 35 0 - 35 0 - 35 0 - 35
Expansion tank Litres 12 12 - 10

 

External unit parametres POWER INVERTER
PUD-SWM80YAA PUD-SWM100YAA PUD-SWM120YAA
HEATING (C) Power / Energy class / SCOP at 35°C / ɳs % kW / reit. / SCOP / % 8/A++/3,45/138 10/A++/3,63/145 12/A++/3,48/139
(C) Power / Energy class / SCOP at 55°C / ɳs % kW / reit. / SCOP / % 8/A+/2,73/109 10/A+/2,73/109 12/A+/2,7/108
A7/W35 / Capacity / el. consumption / COP kW / kW / COP 6,0/1,26/4,76 8,0/1,6/5,0 10,0/2,13/4,70
Capacity at -15°C/+35°C kW 7.3 9 10.4
Capacity at -15°C/+50°C kW 6.6 8.5 9.5
Capacity at -25°C/+45°C kW 4.7 6.9 8
Capacity at -28°C/+45°C kW - - -
Min-Nom-Max capacity at A2/W35 kW 3,1 - 8,0 - 9,3 3,2 - 10,0 - 12,1 3,2 - 12,0 - 12,7
Min-Nom-Max capacity at A7/W45 kW 2,2 - 6,0 - 8,2 2,3 - 8,0 - 10,0 2,3 - 10,0 - 12,1
Dimensions (W x H x D)   mm 1050 x 1020 x 480 1050 x 1020 x 480 1050 x 1020 x 480
Weight   kg 114 120 120
Work temperature (heat / cool)   °C -25°C -25°C -25°C
Sound level (nominal heating)   A 42 44 46
Sound level (max heating)   A 56 59 60
Piping Ø (liquid/gas)   inches 1/4'' / 1/2'' 1/4'' / 1/2'' 1/4'' / 1/2''
Min/Max pipe length   m 2-30 2-30 2-30
Max. Height   m 30 30 30
Fuse   A 3x16 3x16 3x16
Work current   A 8 10 12
Electrical data   F / V / Hz 400/3/50 400/3/50 400/3/50
Flow (min-max)   l/min 9 - 22,9 14,3 - 34,4 14,3 - 34,4
Delivered piping length   m 15 15 15
Reagent     R32 R32 R32
GWP     675 675 675
Nom. Reagent amount Weight kg 1.3 1.6 1.6
CO2 ekv. ton. 0.88 1.08 1.08
Max. Reagent amount Weight kg 1.6 1.8 1.8
CO2 ekv. ton. 1.08 1.24 1.24