Multifunctional tank HYG BR, with a flow-through hot water heat exchanger for hygienic hot water production and an additional heating heat exchanger. Designed for connection to one or more heating sources, the additional heating heat exchanger allows you to connect additional equipment that uses a different heat carrier (e.g. solar collector or heat pump).
Main product features:
- Additional removable insulation with a thickness of 100 mm and a durable PVC outer shell in RAL 9006 color.
- Insulation material used in all models: soft PU, fleece.
- Flow-through hot water heat exchanger made of sanitary stainless steel.
- All threads are internal. Inlet/outlet location – 90 degree angle for easy and convenient installation. Can be installed in the corner of the boiler room.
- Easy installation.
- Convenient inspection opening.
Energy efficiency:
- Directive 2010/30/EU, Regulation 812/2013.
- Class C.
The technical data for the product can be viewed below; see the gallery for explanations of the dimensions.
Available for order
Can be combined with:
1,200.00 €
Price with VAT
max) ? (count = max) : null)">
HYG BR 500 | HYG BR 800 | HYG BR 1000 | |||||||
Capacity | L | 500 | 800 | 1000 | |||||
Capacity of water tank DHW / Buffer tank | L1/L2 | 22/478 | 25/775 | 25/975 | |||||
Height without insulation / with insulation | H, Hi, mm | 1710/1750 | 1850/1890 | 2040/2090 | |||||
Mounting height | mm | 1720 | 1865 | 2074 | |||||
Diameter without insulation / with insulation | D, mm | Ø 650/850 | Ø 790/990 | Ø 790/990 | |||||
Heat exchange surface | E, m2 | 5,5 | 6,11 | 6,11 | |||||
Lower heat exchanger coil S1 | S1, m2 | 1,7 | 2,9 | 3,0 | |||||
Heat exchange surface | |||||||||
Lower heat exchanger coil – capacity S1 | L | 10,5 | 17,9 | 18,5 | |||||
Heating power of the lower / upper coil | kW | 37 | 72 | 75 | |||||
(from an additional heat source) | |||||||||
Lower / Upper Productivity 80оС/60оС (from an additional heat source) | L/h | 1590 | 3095 | 3224 | |||||
Recommended Absorber Heat exchange surface of Solar Collectors | m2 | 8,00 | 12,00 | 14,00 | |||||
Operating pressure/Max. coil temperature | bar/0C | 16/110 | 16/110 | 16/110 | |||||
Operating pressure / Max. buffer temp | bar/0C | 3/95 | 3/95 | 3/95 | |||||
Operating pressure / Max. DHW tube temp. | bar/0C | 6/95 | 6/95 | 6/95 | |||||
Weight without insulation / with insulation | kg, kg i | 142/154 | 188/204 | 210/228 | |||||
Recommended boiler size, connected to | kW | 44 | 75 | 75 | |||||
buffer tank | |||||||||
Continuous outflow 10/45°C, buffer tank is charged to 65°C | Е, 10/45°C, L/h | 1080 | 1840 | 1840 | |||||
Continuous outflow 10/38°C , buffer tank is charged to 65°C. | Е, 10/38°C, L/h | 1350 | 2300 | 2300 | |||||
Single discharge capacity up to 38°C (when the buffer is charged to 65°C) | Е, 10/38°C, L | 375 | 580 | 790 | |||||
ΔT -temperature difference between buffer tank and | Е, ΔT | 6/8/12 | 3.5/5/8 | 3.5/5/8 | |||||
DHW at flow rate 30/40/50 liters/minute | |||||||||
Water stratification unit | Ø, mm | Ø140 | Ø140 | Ø140 | |||||
Boiler heat carrier outlet | С1, mm | Rp11/2”/150 | Rp11/2”/170 | Rp11/2”/170 | |||||
Boiler heat carrier outlet | С2, mm | Rp11/2”/150 | Rp11/2”/170 | Rp11/2”/170 | |||||
Boiler heat carrier outlet | C3, mm | Rp11/2”/150 | Rp11/2”/170 | Rp11/2”/170 | |||||
Outlet heat carrier/lower coil S1 | S1o, mm | Rp1”/325 | Rp1”/350 | Rp1”/390 | |||||
Boiler heat carrier | С4, mm | Rp11/2”/430 | Rp11/2”/470 | Rp11/2”/500 | |||||
Boiler heat carrier | С5, mm | Rp11/2”/1030 | Rp11/2”/1050 | Rp11/2”/1210 | |||||
Boiler heat carrier | С6, mm | Rp11/2”/1030 | Rp11/2”/1050 | Rp11/2”/1210 | |||||
Heat carrier intlet | С7, mm | Rp11/2”/1450 | Rp11/2”/1550 | Rp11/2”/1740 | |||||
Heat carrier intlet | C8, mm | Rp11/2”/1450 | Rp11/2”/1550 | Rp11/2”/1740 | |||||
Inlet heat carrier/lower coil S1 | S1i, mm | Rp1”/775 | Rp1”/845 | Rp1”/930 | |||||
Heat carrier intlet | C11, mm | Rp11/2”/1360 | Rp11/2”/1410 | Rp11/2”/1570 | |||||
Sensor sleeve | А1, mm | Rp1/2”/540 | Rp1/2”/590 | Rp1/2”/620 | |||||
Sensor sleeve | А2, mm | Rp1/2”/650 | Rp1/2”/710 | Rp1/2”/770 | |||||
Sensor sleeve | А3, mm | Rp1/2”/1140 | Rp1/2”/1160 | Rp1/2”/1320 | |||||
Sensor sleeve | А4, mm | Rp1/2”/1420 | Rp1/2”/1520 | Rp1/2”/1700 | |||||
Boiler heat carrier / Electric heating element | В, mm | Rp11/2”/900 | Rp11/2”/930 | Rp11/2”/1050 | |||||
Air Vent | F, mm | Rp11/2”/1710 | Rp11/2”/1850 | Rp11/2”/2040 | |||||
Inlet/outlet DHW coil (tube) | Еi/Eo, mm | 250/1480 | 270/1580 | 310/1760 | |||||